FreeBSD Device Polling Results for Gigabit Copper
In my post FreeBSD Device Polling I ran my tests over Gigabit fiber connections. I thought I would repeat the tests for Gigabit copper, connected by normal straight-through cables. (One benefit of Gigabit copper Ethernet NICs is there's no need for crossover cables.)
Although I booted my two test boxes, asa633 and poweredge, with kernels offering polling, neither interface had polling enabled by default. This is asa633's NIC:
This is poweredge's NIC.
First I ran unidirectional TCP tests, from asa633 to poweredge, without polling.
Here is what the server saw.
Interrupt levels for both systems was similar to the Gigabit copper results.
Here is the change with polling enabled via 'ifconfig em1 polling'. First, the client.
Now the server.
Polling didn't improve the situation much for TCP.
Here are the results for unidirectional UDP tests, without polling.
This is the client.
Notice the huge drops. Here is the server.
Here are results with polling enabled.
The client:
Now the server.
Like the copper tests, polling really helps with UDP performance.
Given that polling can be enabled and disabled at will via ifconfig, I would like to see 'options DEVICE_POLLING' added to the GENERIC FreeBSD kernel.
Although I booted my two test boxes, asa633 and poweredge, with kernels offering polling, neither interface had polling enabled by default. This is asa633's NIC:
em1: flags=8843mtu 1500
options=b
inet6 fe80::20e:cff:feba:e726%em1 prefixlen 64 scopeid 0x4
inet 172.16.7.1 netmask 0xffffff00 broadcast 172.16.7.255
ether 00:0e:0c:ba:e7:26
media: Ethernet autoselect (1000baseTX)
status: active
This is poweredge's NIC.
em1: flags=8843mtu 1500
options=b
inet6 fe80::207:e9ff:fe11:a0a0%em1 prefixlen 64 scopeid 0x4
inet 172.16.7.2 netmask 0xffffff00 broadcast 172.16.7.255
ether 00:07:e9:11:a0:a0
media: Ethernet autoselect (1000baseTX)
status: active
First I ran unidirectional TCP tests, from asa633 to poweredge, without polling.
asa633:/root# iperf -c 172.16.7.2 -t 60 -i 5
------------------------------------------------------------
Client connecting to 172.16.7.2, TCP port 5001
TCP window size: 32.5 KByte (default)
------------------------------------------------------------
[ 3] local 172.16.7.1 port 58672 connected with 172.16.7.2 port 5001
[ 3] 0.0- 5.0 sec 90.2 MBytes 151 Mbits/sec
[ 3] 5.0-10.0 sec 91.1 MBytes 153 Mbits/sec
[ 3] 10.0-15.0 sec 90.0 MBytes 151 Mbits/sec
[ 3] 15.0-20.0 sec 91.2 MBytes 153 Mbits/sec
[ 3] 20.0-25.0 sec 89.8 MBytes 151 Mbits/sec
[ 3] 25.0-30.0 sec 90.9 MBytes 153 Mbits/sec
[ 3] 30.0-35.0 sec 91.7 MBytes 154 Mbits/sec
[ 3] 35.0-40.0 sec 92.0 MBytes 154 Mbits/sec
[ 3] 40.0-45.0 sec 89.9 MBytes 151 Mbits/sec
[ 3] 45.0-50.0 sec 90.1 MBytes 151 Mbits/sec
[ 3] 50.0-55.0 sec 90.4 MBytes 152 Mbits/sec
[ 3] 55.0-60.0 sec 91.0 MBytes 153 Mbits/sec
[ 3] 0.0-60.0 sec 1.06 GBytes 152 Mbits/sec
Here is what the server saw.
poweredge:/root# iperf -s -B 172.16.7.2
------------------------------------------------------------
Server listening on TCP port 5001
Binding to local address 172.16.7.2
TCP window size: 64.0 KByte (default)
------------------------------------------------------------
[ 4] local 172.16.7.2 port 5001 connected with 172.16.7.1 port 58672
[ 4] 0.0-60.0 sec 1.06 GBytes 152 Mbits/sec
Interrupt levels for both systems was similar to the Gigabit copper results.
Here is the change with polling enabled via 'ifconfig em1 polling'. First, the client.
asa633:/root# iperf -c 172.16.7.2 -t 60 -i 5
------------------------------------------------------------
Client connecting to 172.16.7.2, TCP port 5001
TCP window size: 32.5 KByte (default)
------------------------------------------------------------
[ 3] local 172.16.7.1 port 52789 connected with 172.16.7.2 port 5001
[ 3] 0.0- 5.0 sec 79.2 MBytes 133 Mbits/sec
[ 3] 5.0-10.0 sec 76.3 MBytes 128 Mbits/sec
[ 3] 10.0-15.0 sec 80.4 MBytes 135 Mbits/sec
[ 3] 15.0-20.0 sec 123 MBytes 207 Mbits/sec
[ 3] 20.0-25.0 sec 126 MBytes 212 Mbits/sec
[ 3] 25.0-30.0 sec 110 MBytes 185 Mbits/sec
[ 3] 30.0-35.0 sec 89.1 MBytes 149 Mbits/sec
[ 3] 35.0-40.0 sec 77.0 MBytes 129 Mbits/sec
[ 3] 40.0-45.0 sec 76.8 MBytes 129 Mbits/sec
[ 3] 45.0-50.0 sec 103 MBytes 172 Mbits/sec
[ 3] 50.0-55.0 sec 128 MBytes 215 Mbits/sec
[ 3] 55.0-60.0 sec 120 MBytes 201 Mbits/sec
[ 3] 0.0-60.0 sec 1.16 GBytes 166 Mbits/sec
Now the server.
poweredge:/root# iperf -s -B 172.16.7.2
------------------------------------------------------------
Server listening on TCP port 5001
Binding to local address 172.16.7.2
TCP window size: 64.0 KByte (default)
------------------------------------------------------------
[ 4] local 172.16.7.2 port 5001 connected with 172.16.7.1 port 52789
[ 4] 0.0-60.0 sec 1.16 GBytes 166 Mbits/sec
Polling didn't improve the situation much for TCP.
Here are the results for unidirectional UDP tests, without polling.
This is the client.
asa633:/root# iperf -c 172.16.7.2 -u -t 60 -i 5 -b 500M
------------------------------------------------------------
Client connecting to 172.16.7.2, UDP port 5001
Sending 1470 byte datagrams
UDP buffer size: 9.00 KByte (default)
------------------------------------------------------------
[ 3] local 172.16.7.1 port 60193 connected with 172.16.7.2 port 5001
[ 3] 0.0- 5.0 sec 129 MBytes 217 Mbits/sec
[ 3] 5.0-10.0 sec 129 MBytes 217 Mbits/sec
[ 3] 10.0-15.0 sec 129 MBytes 217 Mbits/sec
[ 3] 15.0-20.0 sec 127 MBytes 212 Mbits/sec
[ 3] 20.0-25.0 sec 129 MBytes 217 Mbits/sec
[ 3] 25.0-30.0 sec 129 MBytes 217 Mbits/sec
[ 3] 30.0-35.0 sec 129 MBytes 217 Mbits/sec
[ 3] 35.0-40.0 sec 129 MBytes 217 Mbits/sec
[ 3] 40.0-45.0 sec 129 MBytes 217 Mbits/sec
[ 3] 45.0-50.0 sec 129 MBytes 216 Mbits/sec
[ 3] 50.0-55.0 sec 129 MBytes 216 Mbits/sec
[ 3] 0.0-60.0 sec 1.51 GBytes 216 Mbits/sec
[ 3] Sent 1102470 datagrams
[ 3] Server Report:
[ 3] 0.0-60.0 sec 787 MBytes 110 Mbits/sec 0.042 ms 541153/1102469 (49%)
[ 3] 0.0-60.0 sec 1 datagrams received out-of-order
Notice the huge drops. Here is the server.
poweredge:/root# iperf -s -u -B 172.16.7.2
------------------------------------------------------------
Server listening on UDP port 5001
Binding to local address 172.16.7.2
Receiving 1470 byte datagrams
UDP buffer size: 41.1 KByte (default)
------------------------------------------------------------
[ 3] local 172.16.7.2 port 5001 connected with 172.16.7.1 port 60193
[ 3] 0.0-60.0 sec 787 MBytes 110 Mbits/sec 0.042 ms 541153/1102469 (49%)
[ 3] 0.0-60.0 sec 1 datagrams received out-of-order
Here are results with polling enabled.
The client:
asa633:/root# iperf -c 172.16.7.2 -u -t 60 -i 5 -b 500M
------------------------------------------------------------
Client connecting to 172.16.7.2, UDP port 5001
Sending 1470 byte datagrams
UDP buffer size: 9.00 KByte (default)
------------------------------------------------------------
[ 3] local 172.16.7.1 port 53387 connected with 172.16.7.2 port 5001
[ 3] 0.0- 5.0 sec 163 MBytes 274 Mbits/sec
[ 3] 5.0-10.0 sec 164 MBytes 275 Mbits/sec
[ 3] 10.0-15.0 sec 164 MBytes 275 Mbits/sec
[ 3] 15.0-20.0 sec 164 MBytes 275 Mbits/sec
[ 3] 20.0-25.0 sec 164 MBytes 275 Mbits/sec
[ 3] 25.0-30.0 sec 164 MBytes 275 Mbits/sec
[ 3] 30.0-35.0 sec 163 MBytes 274 Mbits/sec
[ 3] 35.0-40.0 sec 164 MBytes 275 Mbits/sec
[ 3] 40.0-45.0 sec 164 MBytes 275 Mbits/sec
[ 3] 45.0-50.0 sec 164 MBytes 275 Mbits/sec
[ 3] 50.0-55.0 sec 164 MBytes 275 Mbits/sec
[ 3] 0.0-60.0 sec 1.92 GBytes 275 Mbits/sec
[ 3] Sent 1401731 datagrams
[ 3] Server Report:
[ 3] 0.0-60.0 sec 1.86 GBytes 267 Mbits/sec 0.023 ms 40962/1401730 (2.9%)
[ 3] 0.0-60.0 sec 1 datagrams received out-of-order
Now the server.
poweredge:/root# iperf -s -u -B 172.16.7.2
------------------------------------------------------------
Server listening on UDP port 5001
Binding to local address 172.16.7.2
Receiving 1470 byte datagrams
UDP buffer size: 41.1 KByte (default)
------------------------------------------------------------
[ 3] local 172.16.7.2 port 5001 connected with 172.16.7.1 port 53387
[ 3] 0.0-60.0 sec 1.86 GBytes 267 Mbits/sec 0.024 ms 40962/1401730 (2.9%)
[ 3] 0.0-60.0 sec 1 datagrams received out-of-order
Like the copper tests, polling really helps with UDP performance.
Given that polling can be enabled and disabled at will via ifconfig, I would like to see 'options DEVICE_POLLING' added to the GENERIC FreeBSD kernel.